FeuTechnik
  • Home
  • Product
  • References
  • About Us
  • Contact
  • English
    • Čeština
    • Français
    • Deutsch
    • Italiano
    • Latviešu
    • Lietuvos
    • polski
    • Slovenčina
    • Español
    • Белару́ская
    • Hrvatski
    • Ελληνικα
    • Português
    • Türkçe
  • Search
  • Menu

RELIABLE »

VERY EASY TO INSTALL »

DOES NOT REQUIRE POWER SUPPLY »

DOES NOT CAUSE CORROSION OF ENGINE PARTS »

Automatic fire detection
and suppression systems

Dedicated to buses with Electrical, CNG, LNG, Hydrogen,
Hybrid drives as well as Conventional drives

RELIABLE »

VERY EASY TO INSTALL »

DOES NOT REQUIRE POWER SUPPLY »

DOES NOT CAUSE CORROSION OF ENGINE PARTS »

Dedicated to buses with Electrical,
CNG, LNG, Hydrogen, Hybrid drives
as well as Conventional drives

Automatic fire detection
and suppression systems

FeuTechnik DualMax

FeuTechnik MAX

Powder suppression system for heating unit and other components with reliable pneumatic detection, certified in accordance to UNECE R107.06

FeuTechnik CLEAN AGENT

Manually activated system with NOVEC gas. Blows out flames from protected component and as condensed gas – significantly reduces possibility of reignition.

How it works

1
2
3
1

in case of fire, the detecting duct FeuTechnik is burnt

2

activates the cylinder valve

3

releases the distribution of the extinguishing agent

In case of fire FeuTechnik detection tube is ruptured and the cylinder’s valve is activated. This releases distribution of extinguishing agent by means of the extinguishing nozzles system. The extinguishing agent quickly fills the area of whole engine compartment, absorbs flammable liquids and prevents re-ignition. Dry chemical powder is non-toxic, suitable for use in case of fire caused by an electric current short circuit and any flammable liquids and gases. The whole system is provided with a pressure sensor connected to the visual and audio information to the driver.

FeuTechnik detection tube ideally suits for fire detection in buses, because it tolerates all kinds of vibration, contamination and extreme temperatures in which buses work. Due to pneumatic control system operation does not require any electricity from the bus and does not have additional burden on the electrical system of the vehicle.

It is the most appropriate medium recommended for ABC group fires: 

A- Fire of solids that are decomposed under the influence of heat and emit flammable gases and vapours. 

B- Fire of flammable liquids and substances melting under the influence of heat. 

C- Fire of flammable gases. 

The system is provided with a pressure sensor connected to a central unit controlling visual and sound information to the operator. The detecting tube FeuTechnik is ideally suited to detect fire as it tolerates all kinds of vibrations, contamination and extreme temperatures in which machines operate. With pneumatic control, activation does not require electrical energy and does not generate any additional burden to the wiring system in the vehicle. 

  • The extinguishing agent

    applied in the automatic fire extinguishing system FeuTechnik is a fine powder – monoammonium phosphate (NH4H2PO4), known as ABC or a multi-task powder. 

  • Firefighting cylinder

    The chemical extinguishing powder ABC is stored in a pressure steel cylinder filled with compressed nitrogen.

    Each cylinder is provided with a nickel-plated brass valve, a manometer to monitor pressure inside the cylinder and a valve connected to the detection system FeuTechnik. 

    Firefighting cylinder

  • Detection tube

    It is resistant to a majority of common chemicals, oils and substances. It performs two functions: fire detection and system activation. The tube is installed in the entire area of potential hazard and connected to the top of the cylinder valve. It is filled in with pressurised nitrogen keeping the system “active”. The detection tube FeuTechnik is sensitive to temperature and energy emissions; when a fire arises it is burnt and the reduced pressure activates the extinguishing system. 

  • Electrical pressure sensor

    The sensor monitors pressure in the system, controls the system and/or power supply or power shortage of all electrical devices.  The element may be connected to the end of the detection tube or fitted on the cylinder valve in order to perform other electrical functions that may be required. FeuTechnik that all systems use two pressure sensors connected with visual and sound information for the driver. 

    Electrical pressure sensor

  • Extinguishing pipes and nozzles

    The extinguishing agent is distributed in the entire engine chamber with extinguishing tubes made of stainless steel ended with nozzles.  The nozzles are multi-directional to distribute the agent in multiple directions so that the powder gets to each place of the chamber.  

  • Visual and sound information to the driver

    This is a set of devices installed in the driver’s cabin.  The devices are as follows: alarm siren generating a modulating sound signal and a flashing alarm lamp.  The devices are to inform the driver that the system has been activated. 

    Visual and sound information to the driver

  • Self-diagnosing module

    Within a short time, the module informs on effects of unauthorised interference in the system. It monitors the condition of key system elements such as: pressure level, position of the lever of the ball valve on the cylinder and electrical connection.  

Learn More

Please download the brochure below for further information

FeuTechnik Brochure
R107 V6 Tests

References & Certificates

Ministerio de Industria, Comercio y Turismo

FeuTechnik Homologation

Read more
Scientific and Research Centre for Fire Protection

National Research Institute

Read more
Miejskie Zakłady Autobusowe Sp. z o.o.

Private limited company

Read more
Related links
Contracts

.

Read more
AutoWatch Polska Sp. z o.o.

Private limited company

Read more

About Us

FeuTechnik Ltd.

FeuTechnik is one of the biggest in Europe producers and suppliers of Automatic Fire Detection and Suppression Systems. We offer fire extinguishing systems for city busses and vehicles. Improving road safety is our mission.

We focused on cooperation with bus manufacturers and public transportation companies from Poland and Europe. FeuTechnik systems are installed in factories of such producers as: SOLARIS, MAN, VOLVO, AUTOSAN, SOR.

Professional knowledge and well-established position on the bus market have allowed us to develop cooperation with many of the European bus manufacturers and transportation companies.

Our clients recommend FeuTechnik Ltd. as a trustworthy partner which fulfils its obligations to the highest standards.

Growing trust in our company is proved by constantly increasing to over 3500 pcs number of buses equipped with our systems traveling on Polish and European roads.

We protect

GET IN TOUCH

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

This contact form is deactivated because you refused to accept Google reCaptcha service which is necessary to validate any messages sent by the form.

FeuTechnik Sp z o.o.

KRS 0000779184
NIP 1132995888
REGON 382946043

Address

ul. Lotnicza 18
04-192 Warszawa
Polska

Contact

E-mail: info@feutechnik.eu
Phone: +48 22 611 00 16
Fax: +48 22 610 94 61

  • Privacy policy
  • GDPR
  • integence.pl
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

OK×

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Privacy Policy

You can read about our cookies and privacy settings in detail on our Privacy Policy Page.

Privacy policy
Accept settingsHide notification only